smaksol logo

SMAKSol Elektrarna

 

 

telefon: +386 (0)59 21 7817, +386 (0)59 21 7816 faks: +386 (0)1 520 5261, email: info@smaksol.si

SMAKSol Protect

Overvoltage Protection for Photovoltaic (PV) Power Generating Systems (Junction and Overvoltage Protection Box)

SMAKSol Protect is important part of your Solar Power System and protects people, Solar Power System and Buildings. SMAK Protect has additional function - it also junction box.

For Photovoltaic Systems placed on buildings Without External Lightning Protection

SMAKSol Protect

For Photovoltaic Systems placed on buildings With External Lightning Protection

SMAKSol Protect

Two main types 1 to 1 and 4 to 1:

 

Two main types 1 to 1 and 4 to 1:



NEW - SMAKSol Protect with Switch (Overvoltage Protection and Switch Box)

For Photovoltaic Systems placed on buildings Without External Lightning Protection

For Photovoltaic Systems placed on buildings With External Lightning Protection

Only version 1 to 1:

Only version 1 to 1:

  • SMAKSol Protect CI/B+C 1DC1DC MC + SW:

How to Connect SMAKSol Protect into a Photovoltaic System

Connection of SMAKSol Protect with Photovoltaic Park/Area/String/Module Outside of a Building
SMAKSol Protect - Connection

Connection of SMAKSol Protect with Photovoltaic Park/Area/String/Module inside of a Building
SMAKSol Protect - PV Connection in Building

CLASS II,C - V PROTEC C(R) 40
Features :
- For Photovoltaic Systems
- In = 20kA / pole
- Imax = 40kA / pole
- MOV
- Compact Housing

Product Summary :The PV PROTEC C(R) 40 series of over voltage surge protective devices has been developed to protect against indirect lightning discharges and is intended to protect photovoltaic systems.The circuit topology consists of two (three)varistor stages each protected by a thermal disconnection device.
Category IEC / EN / VDE: Class II / Type 2 / C
Location of use: Branch sub-distribution boards
Protection modes: (+) - PE, (-) – PE
Protective element: High energy MOVs
Surge discharge ratings: In = 20kA, Imax = 40kA
Internal protection and safety: Thermal disconnector
Status indication: Mechanical flag + remote contacts (R)

CLASS I, B+C - PV PROTEC BS(R) 12.5
Features :
- For Photovoltaic Systems
- Iimp = 12.5kA / pole
- Imax = 40kA / pole
- High Energy MOV
- Compact Housing

Product Summary :The PV PROTEC BS(R) 12.5 series of over voltage surge protective devices has been developed to protect against partial direct and indirect lightning discharges and is intended to protect photovoltaic systems. The circuit topology consists of two varistor stages each protected by a thermal disconnection device.
Category IEC / EN / VDE: Class I / Type 1 / B+C
Location of use: Photovoltaic systems - PV module side
Protection modes: (+) - PE, (-) - PE
Protective element: High Energy MOVs
High surge discharge ratings: Iimp = 12.5kA, Imax = 40kA
Internal protection and safety: Separate thermal disconnector for each MOV block
Status indication: Mechanical flag + remote contacts (R)